- Testing Types
- Single Actuation Content (SAC) Through Container Life Testing
Terms and Conditions
Sample Submission Form
Overview
Single Actuation Content (SAC) is the amount of active pharmaceutical ingredient delivered in an individual actuation of a nasal spray device.
SAC through container life testing evaluates whether a multidose product maintains consistent drug delivery at predefined stages of its labelled use period. Unlike pump delivery or shot weight, which measures the mass of formulation discharged, SAC measures the actual drug content emitted per actuation. This distinction is particularly important for suspension formulations, where consistent pump delivery does not necessarily establish consistent drug content.
SAC testing involves controlled actuation procedures, appropriate dose collection methods and suitable quantitative analytical techniques to assess drug content across the intended use of a nasal spray product.
At PLS Analytical, testing can evaluate dose delivery at defined stages of container life, assess priming and repriming behaviour, and compare test and reference products. The approach can also be used to investigate potential changes in delivered drug content associated with storage, formulation changes, pump or actuator substitutions and manufacturing modifications.
Consistent drug delivery is an important aspect of nasal spray product performance. SAC testing helps determine whether the intended amount of active drug is delivered throughout the labelled use period, while identifying potential variations associated with formulation uniformity, pump performance or individual units.
By generating quantitative test-to-reference data, SAC studies provide valuable insight into dose delivery consistency and product variability. These findings can support product characterization, in vitro bioequivalence programmes, control strategies and lifecycle assessments.
Testing Services
PLS Analytical performs single actuation content testing to support dose delivery assessment, product characterization, comparative studies, and in vitro bioequivalence programmes.
Beginning-, Middle- and End-of-Life Testing
Beginning-, Middle- and End-of-Life Testing
Evaluation of delivered drug content at defined stages of container life to assess dose consistency throughout the labelled number of actuations.
Priming and Repriming Evaluation
Priming and Repriming Evaluation
Assessment of the number of actuations required to establish adequate dose delivery initially and following specified periods of device non-use.
Comparative SAC Studies
Comparative SAC Studies
Quantitative comparison of test and reference nasal products to evaluate drug delivery consistency and relevant between-unit, within-unit and batch-to-batch variability.
Stability and Device Change Assessment
Stability and Device Change Assessment
Evaluation of potential changes in delivered drug content associated with storage, formulation changes, pump or actuator substitutions and manufacturing modifications.
Unit-Dose Product Evaluation
Unit-Dose Product Evaluation
For unit-dose devices, assessment of drug content delivered per unit and unit-to-unit variability using an appropriate study design, rather than a conventional multidose container-life sequence.
Advantages
SAC testing provides quantitative evidence of dose delivery consistency across container life, supporting product comparability and lifecycle quality assessment.
Assess Dose Consistency
Evaluate whether the delivered drug content remains consistent across the intended product use period.
Detect Potential Delivery Issues Early
Identify variations that may arise from formulation nonuniformity, pump performance or drug-content delivery.
Strengthen Product Comparability
Generate quantitative data to evaluate differences between test and reference products under defined testing conditions.
Support Development and Quality Assessment
Use SAC data to inform product characterization, in vitro bioequivalence studies, control strategies and lifecycle assessments.